{"id":308,"date":"2018-03-11T12:09:02","date_gmt":"2018-03-11T03:09:02","guid":{"rendered":"http:\/\/www.wakenbtech.co.jp\/eng\/wp\/?page_id=308"},"modified":"2025-04-02T13:51:02","modified_gmt":"2025-04-02T04:51:02","slug":"maxcell-mlf","status":"publish","type":"page","link":"https:\/\/www.wakenbtech.co.jp\/eng\/products\/instruments\/maxcell-mlf\/","title":{"rendered":"MaxCell MLF, Large Capacity CO2 Incubator"},"content":{"rendered":"<hr \/>\n<p><head>\n \t \t \t<link rel=\"stylesheet\" href=\"\/eng\/wp\/wp-content\/themes\/tcl\/css\/utility.css\">\n \t \t \t<link rel=\"stylesheet\" href=\"\/eng\/wp\/wp-content\/themes\/tcl\/css\/modules.css\">\n<\/head><\/p>\n<h2>Large capacity CO2 incubator for 40\/52 layer stack plate<\/h2>\n<h4>The MaxCell MLF (Multi Layer Flask)\u00a0 is the large capacity incubator optimized for Cell Factory (Thermofisher), or CellSTACK (Corning) or HYPERStack (Corning) flasks used for large scale cell, virus, protein and exosome productions. The flasks are firmly held in the special carrier in the incubator. The forcibly gas infusion model is available. It supplies CO2 gas into multi-layer flasks so that CO2 concentration and, eventually, pH value in each layer is kept stable. Gas hose connections are convenient and easy to make.<\/h4>\n<div align=\"center\"><\/div>\n<h5 class=\"subtitle\">Details<\/h5>\n<ul>\n<li><strong>Compatible with 40-stacked Cell Factory\/HYPERStack<\/strong><br \/>\nSingle chamber model can accomodate 4 sets of 40\/50-layer flasks. Two chambered model can accomodate 8 sets of 40\/50-layer flasks.<br \/>\n<span class=\"fwB p_fwB\">*4-chamber model (MLF4) that can accomodate 16 pcs of 40-layer flasks is also available. Please contact us for the details of the 4-chamber model.<\/span><\/li>\n<li><strong>Special Carrier is available<\/strong><br \/>\nSpecial carrier developed for the MLF is available.It can be easily docked with the MLF and allows an operator to slide the upper-cart (flask holder) into MLF easily, which accomodates 40\/52-layer flasks.<\/li>\n<li><strong>Frocibly gas infusion moel<\/strong>MLF has forcibly gas infusion functionality with which CO2 gas is forcibly injectedd into multi-layer flasks in order to maintein pH value evenly in each flask layer.<\/li>\n<li><strong>Easy gas hose connections (Forcibly gas infusion model)<\/strong><br \/>\nGas tubes with a quick check valve connector make it easy to realize firm and leak-free connections with flasks.<\/li>\n<li><strong>Front Window<\/strong><br \/>\nThe large window and the LED light in the chamber allows operator to check the flasks placed in the chamber without opening the door.<\/li>\n<li><strong>Multifunctional LCD touchscreen<\/strong><br \/>\nThe LCD touch screen provides operators with information like operation log, the number of culture flasks in use and each parameter.<\/li>\n<li><strong>External output<\/strong><br \/>\nAn external can be retrofitted to the front panel of MLF. The recorder keeps the record of each controlled parameter.<\/li>\n<\/ul>\n<p class=\"p_mt30 mt30 p_mb30 mb30\">*The special carrier (trolley) and upper-cart (flask golder) are available separately. With the special carrier and upper-cart, multi-layer flasks can be seasily handled. Automatic 40-layer flask mnipulator manufactured by Shikoku Instrument is also available. If the number of flask increases, this manipulator robot is necessary and it can be used with our MLF incubator because special carrier and upper-cart are compatible with MLF.<\/p>\n<div class=\"wc-shortcodes-accordion wc-shortcodes-item wc-shortcodes-accordion-default  wc-shortcodes-accordion-layout-box\" data-behavior=\"autoclose\" data-start-state=\"default\">\n<div class=\"wc-shortcodes-accordion-trigger \"><a href=\"#\">Specification<\/a><\/div>\n<div class=\"wc-shortcodes-accordion-content-wrapper\">\n<div class=\"wc-shortcodes-accordion-content wc-shortcodes-content\">\n\n<table id=\"tablepress-16\" class=\"tablepress tablepress-id-16\">\n<thead>\n<tr class=\"row-1 odd\">\n\t<th colspan=\"2\" class=\"column-1\">Model<\/th><th class=\"column-3\">MLF1<\/th><th class=\"column-4\">MLF2<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n\t<td colspan=\"2\" class=\"column-1\">Number of chambers<\/td><td class=\"column-3\">1<\/td><td class=\"column-4\">2<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td colspan=\"2\" class=\"column-1\">Supported containers<\/td><td colspan=\"2\" class=\"column-3\">Cell Factory 40-stacked and 52-stacked units(Thermofisher Scientific)<br \/>\nCellSTACK 40-stacked and HYPERStack 36stacked units(Cornig)*<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td rowspan=\"3\" class=\"column-1\">Stable quantity<\/td><td class=\"column-2\">Cell Factory<\/td><td class=\"column-3\">4<\/td><td class=\"column-4\">8<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n\t<td class=\"column-2\">CellSTACK<\/td><td class=\"column-3\">4<\/td><td class=\"column-4\">8<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n\t<td class=\"column-2\">HYPERStack<\/td><td class=\"column-3\">8<\/td><td class=\"column-4\">16<\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n\t<td rowspan=\"3\" class=\"column-1\">Temperature<\/td><td class=\"column-2\">Control range<\/td><td colspan=\"2\" class=\"column-3\">Room temperature +8 to +28 (max. 50C)<\/td>\n<\/tr>\n<tr class=\"row-8 even\">\n\t<td class=\"column-2\">Control accuracy<\/td><td colspan=\"2\" class=\"column-3\">\u00b10.5C (at 37.0C)<\/td>\n<\/tr>\n<tr class=\"row-9 odd\">\n\t<td class=\"column-2\">Distribution accuracy<\/td><td colspan=\"2\" class=\"column-3\">Reference point \u00b1 1.0C (at 37.0C)<\/td>\n<\/tr>\n<tr class=\"row-10 even\">\n\t<td rowspan=\"4\" class=\"column-1\">CO2<\/td><td class=\"column-2\">Sensor<\/td><td colspan=\"2\" class=\"column-3\">Infrared system (IR)<\/td>\n<\/tr>\n<tr class=\"row-11 odd\">\n\t<td class=\"column-2\">Control system<\/td><td colspan=\"2\" class=\"column-3\">Digital PID<\/td>\n<\/tr>\n<tr class=\"row-12 even\">\n\t<td class=\"column-2\">Setting system<\/td><td colspan=\"2\" class=\"column-3\">0 to 18.0%<\/td>\n<\/tr>\n<tr class=\"row-13 odd\">\n\t<td class=\"column-2\">Control accuracy<\/td><td colspan=\"2\" class=\"column-3\">\u00b10.5%<\/td>\n<\/tr>\n<tr class=\"row-14 even\">\n\t<td colspan=\"2\" class=\"column-1\">Chamber capacity (L)<\/td><td class=\"column-3\">1216.0<\/td><td class=\"column-4\">1626.0<\/td>\n<\/tr>\n<tr class=\"row-15 odd\">\n\t<td colspan=\"2\" class=\"column-1\">Internal dimensions (mm)<\/td><td class=\"column-3\">790 (W) x 1182 (D) x 1302 (H)<\/td><td class=\"column-4\">1060 (W) x 1180 (D) x 1300 (H)<\/td>\n<\/tr>\n<tr class=\"row-16 even\">\n\t<td colspan=\"2\" class=\"column-1\">External dimensions (mm)<\/td><td class=\"column-3\">950 (W) x 1354 (D) x 1750 (H)<\/td><td class=\"column-4\">1218 (W) x 1370 (D) x 1750 (H)<\/td>\n<\/tr>\n<tr class=\"row-17 odd\">\n\t<td colspan=\"2\" class=\"column-1\">Weight (kg)<\/td><td class=\"column-3\">410<\/td><td class=\"column-4\">550<\/td>\n<\/tr>\n<tr class=\"row-18 even\">\n\t<td colspan=\"2\" class=\"column-1\">Power supply<\/td><td class=\"column-3\">AC100-240V (50\/60Hz), 800VA<\/td><td class=\"column-4\">AC100-240V (50\/60Hz), 1100VA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-16 from cache -->\n<p>*Please contact us for details.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div align=\"center\">\n<div style=\"width: 640px;\" class=\"wp-video\"><!--[if lt IE 9]><script>document.createElement('video');<\/script><![endif]-->\n<video class=\"wp-video-shortcode\" id=\"video-308-1\" width=\"640\" height=\"360\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"https:\/\/www.wakenbtech.co.jp\/eng\/wp\/wp-content\/uploads\/2018\/10\/MaxCell-MLF.mp4?_=1\" \/><a href=\"https:\/\/www.wakenbtech.co.jp\/eng\/wp\/wp-content\/uploads\/2018\/10\/MaxCell-MLF.mp4\">https:\/\/www.wakenbtech.co.jp\/eng\/wp\/wp-content\/uploads\/2018\/10\/MaxCell-MLF.mp4<\/a><\/video><\/div>\n<\/div>\n<div class=\"wc-shortcodes-item wc-shortcodes-button-center\"><a href=\"\/eng\/wp\/wp-content\/uploads\/2024\/05\/MLF_ENG_compressed.pdf\" class=\"wc-shortcodes-button wc-shortcodes-button-primary wc-shortcodes-button-position-center\" title=\"Download brochure PDF\"><span class=\"wc-shortcodes-button-inner\">Download brochure PDF<\/span><\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Large capacity CO2 incubator for 40\/52 layer stack plate The MaxCell MLF (Multi Layer Flask)\u00a0 is the large cap&#8230;<\/p>\n","protected":false},"author":2,"featured_media":1520,"parent":116,"menu_order":45,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"categories":[5],"tags":[],"_links":{"self":[{"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/pages\/308"}],"collection":[{"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/comments?post=308"}],"version-history":[{"count":69,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/pages\/308\/revisions"}],"predecessor-version":[{"id":4007,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/pages\/308\/revisions\/4007"}],"up":[{"embeddable":true,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/pages\/116"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/media\/1520"}],"wp:attachment":[{"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/media?parent=308"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/categories?post=308"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/tags?post=308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}