{"id":1945,"date":"2019-12-16T10:51:51","date_gmt":"2019-12-16T01:51:51","guid":{"rendered":"https:\/\/www.wakenbtech.co.jp\/eng\/?page_id=1945"},"modified":"2025-09-22T16:27:57","modified_gmt":"2025-09-22T07:27:57","slug":"fogact-the-firtst-decontamination-device","status":"publish","type":"page","link":"https:\/\/www.wakenbtech.co.jp\/eng\/fogact-the-firtst-decontamination-device\/","title":{"rendered":"FOGACT, Portable Decontamination System"},"content":{"rendered":"\n<head>\n<link rel=\"stylesheet\" href=\"\/eng\/wp\/wp-content\/themes\/tcl\/css\/utility.css\">\n<link rel=\"stylesheet\" href=\"\/eng\/wp\/wp-content\/themes\/tcl\/css\/modules.css\">\n<\/head>\n\n<h2>Small disinfection system for placement inside equipment chambers.<\/h2>\n<div style=\"text-align: left;\" align=\"center\">FOGACT is the first decontamination validation device to achieve complete spatial decontamination by fogging a peracetic acid (PAA) disinfectant within the chambers of various laboratory equipment.<\/div>\n<div align=\"center\"><\/div>\n<h5 class=\"subtitle\">Details<\/h5>\n<ul>\n<li>Small and portable, easy to be installed in various types of laboratory equipment.<\/li>\n<li>Generate dry fog of 6\u03bcm diameter droplets by ultrasonic method for effective vaporization.<\/li>\n<li>It does not cause condensation and wet inside the chamber, wiping is not required and there is not risk of secondary contamination.<\/li>\n<li>Easy to use, and automatically calculates the optimal decontamination time based on the initial temperature and humidity inside the chamber.<\/li>\n<li>Actril Cold Sterilant is safe for humans and environment, neutralization and post-treatment not required. There is no residual toxicity.<\/li>\n<li>Utilization of catalytic fan enables quick reduction of residual hydrogen peroxide concentration after completion of decontamination.<\/li>\n<li>Single unit is capable for decontamination up to area of about 0.7m<sup>3<\/sup> (equivalent to safety cabinet with opening width of 1800mm).<\/li>\n<li>This device cannot be singly operated. Please use the device with a peracetic acid disinfectant like Actril or a product at a concentration equal to Actril.<\/li>\n<\/ul>\n\n<h3 class=\"mod_tit05 mt30 p_mt50\">FOGACT Expander<\/h3>\n<div class=\"p_dF\">\n<figure class=\"taC p_taC p_w50per\">\n<img decoding=\"async\" class=\"taC p_taC w90per p_w80per\" src=\"\/eng\/wp\/wp-content\/uploads\/2025\/09\/FOGACT_Expander02.jpg\">\n<\/figure>\n<figure class=\"taC p_taC p_w50per\">\n<img decoding=\"async\" class=\"taC p_taC w90per p_w80per\" src=\"\/eng\/wp\/wp-content\/uploads\/2025\/09\/FOGACT_Expander01-2.jpg\">\n<\/figure>\n<\/div>\n<p>Since the FOGACT is a compact decontamination system, it cannot decontaminate large volume chambers like 870L. However, it can decontaminate such lrage chambers by using the FOGACT Expander. The features of the Expander are as follows.<\/p>\n<ul style=\"list-style:none;\">\n<li>3 unis of FOGACT fog generator can be connected to the Expander.<\/li>\n<li>FOGACT Expander connected to 3 units of FOGACT generator can decontaminate up to 2,100L of chambers.<\/li>\n<li>Just connecting FOGACT generator to the Expander, the generators operate in cordinated manner.<\/li>\n<li>The expander allows operators to shorten the decontamination time.<\/li>\n<li>By using the Expander, FOGACT can decontaminate vertical chambers like lockers.<\/li>\n<\/ul>\n<p class=\"mb30 p_mb50\">Please contact us through the contact page if you are interested in the Expander.<\/p>\n\n<p><div class=\"wc-shortcodes-accordion wc-shortcodes-item wc-shortcodes-accordion-default  wc-shortcodes-accordion-layout-box\" data-behavior=\"autoclose\" data-start-state=\"default\"><\/p>\n<p><div class=\"wc-shortcodes-accordion-trigger \"><a href=\"#\">Specification<\/a><\/div><div class=\"wc-shortcodes-accordion-content-wrapper\"><div class=\"wc-shortcodes-accordion-content wc-shortcodes-content\"><\/p>\n<div style=\"overflow: scroll;\">\n<table id=\"tablepress-22\" class=\"tablepress tablepress-id-22\">\n<thead>\n<tr class=\"row-1 odd\">\n\t<th class=\"column-1\" style=\"width:40%;\">Catalog number<\/th><th class=\"column-2\" style=\"width:60%;\">FA101<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\">Power supply<\/td><td class=\"column-2\">DC24V (AC Adapter)<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\">Sensor precision<\/td><td class=\"column-2\">Temperature \u00b10.5 \u2103<br \/>\nHumidity \u00b13%<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td class=\"column-1\">Operating temperature range*<\/td><td class=\"column-2\">15 \uff5e 45\u2103<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n\t<td class=\"column-1\">Operating humidity range<\/td><td class=\"column-2\">Up to 80%RH<br \/>\n(Without condensation)<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n\t<td class=\"column-1\">Decontamination volume<\/td><td class=\"column-2\">Up to 0.7m<sup>3<\/sup>\/unit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-22 from cache --><\/div>\n<p>* NOTE: This device cannot be used in an equipment chamber equipped with a cooling source as this will cause condensation. It may also not be possible to use this device in an equipment chamber with extreme temperature variations.<br><\/div><\/div><\/p>\n<p><\/div><\/p>\n<p><div class=\"wc-shortcodes-accordion wc-shortcodes-item wc-shortcodes-accordion-default  wc-shortcodes-accordion-layout-box\" data-behavior=\"autoclose\" data-start-state=\"default\"><\/p>\n<p><div class=\"wc-shortcodes-accordion-trigger \"><a href=\"#\">Ordering information<\/a><\/div><div class=\"wc-shortcodes-accordion-content-wrapper\"><div class=\"wc-shortcodes-accordion-content wc-shortcodes-content\"><\/p>\n<div style=\"overflow: scroll;\">\n<table id=\"tablepress-23\" class=\"tablepress tablepress-id-23\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\" style=\"width:40%;\">Catalog number<\/th><th class=\"column-2\" style=\"width:60%;\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">FA101<\/td><td class=\"column-2\">FOGACT<br \/>\nFog generator, Controller, Temperature and Humidity sensor<br \/>\nMain fan and Catalyst fan\uff65\uff65\uff65\uff65\uff65one of each<br \/>\nAccessories\uff65\uff65\uff65\uff65\uff65one of each<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">FA23<\/td><td class=\"column-2\">Replacement part : Temperature and Humidity sensor<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">FA05<\/td><td class=\"column-2\">Replacement : Main fan<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">PB6001<\/td><td class=\"column-2\">PBio Steri Wiper 1000pcs\/Box<br \/>\ntriple bagged and gamma irradiated, 25 pc\/bag x 4 bags x 10 bags x 1 bag<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">FA30<\/td><td class=\"column-2\">FOGACT Actril continuous supplying unit<br \/>\n FOG generator cover for continuous supplying unit<br \/>\n 300mL bottle<br \/>\n connector for bottle<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">PB900256<\/td><td class=\"column-2\">FOGACT Decontamination Validation Tool<br \/>\nBiological Indicator G.Stearothermophilus 10<sup>6<\/sup> spores\/strip\uff65\uff65\uff65\uff65\uff6525 pcs<br \/>\nTryptic Soy Broth\uff65\uff65\uff65\uff65\uff6525 pcs<br \/>\nClips for BI\uff65\uff65\uff65\uff65\uff654 pcs<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-23 from cache --> \/<\/div>\n<p><\/div><\/div><\/p>\n<p><\/div><\/p>\n\n\n\n<div class=\"wc-shortcodes-item wc-shortcodes-button-center\"><a href=\"\/eng\/wp\/wp-content\/uploads\/2019\/12\/FOGACT-Brochure.pdf\" class=\"wc-shortcodes-button wc-shortcodes-button-primary wc-shortcodes-button-position-center\" title=\"Download brochure PDF\"><span class=\"wc-shortcodes-button-inner\">Download brochure PDF<\/span><\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Small disinfection system for placement inside equipment chambers. FOGACT is the first decontamination validat&#8230;<\/p>\n","protected":false},"author":2,"featured_media":2023,"parent":0,"menu_order":38,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"categories":[5],"tags":[],"_links":{"self":[{"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/pages\/1945"}],"collection":[{"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/comments?post=1945"}],"version-history":[{"count":21,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/pages\/1945\/revisions"}],"predecessor-version":[{"id":4096,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/pages\/1945\/revisions\/4096"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/media\/2023"}],"wp:attachment":[{"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/media?parent=1945"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/categories?post=1945"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.wakenbtech.co.jp\/eng\/wp-json\/wp\/v2\/tags?post=1945"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}